FlexiBowl Wizard

FlexiBowl Wizard#

Problem

Possible Causes

Solutions

Wizard does not start

• Recipe not loaded

• FlexiBowl not connected

• Initial setup not completed

• Load or create a recipe first

• Check FlexiBowl connection

• Complete basic system configuration

Set rotation direction does not match

• CW/CCW selection error

• Visually verify the actual rotation direction

• Correct the selection in the Wizard

Air-blow test does not work

• Compressed air not connected

• Insufficient pressure

• Module not physically present

• Check compressed-air connection

• Increase pressure to 5-6 bar

• Select “FlexiBowl NOT equipped” if the module is absent

Flip test not noticeable

• Compressed air not connected/insufficient

• Pressure regulator closed

• Pneumatic circuit leaks

• Verify compressed air is connected

• Open regulator on control panel

• Verify pressure 5-6 bar

• Inspect fittings for leaks

Calculated parameters not optimal

• Incorrect component characterization

• Wizard uses generic values

• Review selected geometry and behavior

• Accept Wizard parameters as a starting point

• Fine-tune manually in the summary dashboard

Components move during acquisition

• Speed/acceleration too high

• Stabilization pauses absent

• Grip surface not suitable

• Decrease Speed and Accel

• Insert 200-500ms pauses

• Replace grip surface with a more adhesive one

Air blow not effective

• Air pressure insufficient/excessive

• Nozzles clogged

• Verify pressure 5-6 bar

• Clean air-blow nozzles

Parameter changes are not applied

• “Synchronize Parameters” not pressed

• Recipe not saved

ALWAYS click Synchronize Parameters after changes

• Save recipe to make changes permanent

Turn FLB does not work during setup

• FlexiBowl not connected

• Command not configured

• FlexiBowl in error

• Check FlexiBowl connection

• Check FlexiBowl Setup configuration

• Check FlexiBowl READY LED