FlexiBowl Wizard

FlexiBowl Wizard#

Problem

Possible Causes

Solutions

Wizard does not start

• Recipe not uploaded

• FlexiBowl® not connected

• Initial setup not completed

• First upload or create recipe

• Check FlexiBowl® connection

• Complete basic system configuration

Set direction of rotation does not match

• CW/CCW selection error

• Visually verify actual direction of rotation

• Correct selection in the Wizard

Air-blow test does not work

• Compressed air not connected

• Insufficient pressure

• Module not physically present

• Check compressed air connection

• Increase pressure to 5-6 bar

• Select “FlexiBowl® NOT equipped” if module absent

Flip test not noticeable

• Compressed air not connected/insufficient

• Pressure regulator closed

• Pneumatic circuit leaks

• Check connected compressed air

• Open regulator on control panel

• Check pressure 5-6 bar

• Inspect fittings for leaks

Calculated parameters not ideal

• Incorrect component characterisation

• Wizard uses generic values

• Review selected geometry and behaviour

• Accept Wizard Parameters as a starting point

• Manually fine-tune in summary dashboard

Components move during capture

• Speed/acceleration too high

• No stabilisation pauses

• Unsuitable grip surface

• Decrease Speed and Accel

• Insert pauses 200-500ms

• Replace grip surface with more adherent

Blow not effective

• Too much/little air pressure

• Clogged nozzles

• Check pressure 5-6 bar

• Clean air-blow nozzles

Parameter changes do not apply

• ‘Synchronize Parameters’ not pressed

• Recipe not saved

ALWAYS click Synchronize Parameters after changes

• Save recipe to make changes permanent

Turn FLB does not work during setup

• FlexiBowl® not connected

• Command not configured

• FlexiBowl® in error

• Check FlexiBowl® connection

• Check FlexiBowl® Setup

• Check FlexiBowl® READY LED